When the sliding door is converted to a swing door it shall comply with all the requirements of an exit access door.
Sliding door landing requirements.
A top landing is not required where a stairway of not more than two risers is located on the exterior side of the door provided that the door does not swing over the stairway.
A flight of stairs shall not have a vertical rise larger than 12 feet 3658.
Then this section may help you out r311 7 5 landings for stairways.
There shall be a floor or landing on each side of each exterior door.
When we open a door that swings out over a step down our hand on the doorknob guides where we step out and how far.
The landing at an exterior doorway shall not be more than 7 3 4 inches 196 mm below the top of the threshold.
The floor or landing at exterior doors other than the exit door required by section r311 4 1 shall not be required to comply with this requirement but shall have a rise no greater than that permitted in section r311 5 3.
F change in floor level at doors.
Where a door opens over a landing the landing shall be at least as wide as the door and at least 5 feet long.
Regardless of the occupant load there shall be a floor or landing on each side of a door.
The width of each landing shall not be less than the door served.
After all these wise choices are made double check them against the minimum code requirements.
You can eliminate part of the hazard of a door that opens out over a step by using a sliding or pocket door provided the whole assembly is fire rated as most pocket doors are not.
4 a landing may be omitted at the bottom of an exterior stair or ramp provided there is no obstruction such as a gate or door within the lesser of the width of the stair or ramp or a 900 mm for stairs or ramps serving a single dwelling unit and.
A floor or landing is not required at the top of an interior flight of stairs including stairs in an enclosed garage provided a door does not swing over the stairs.
The following is a list of the general requirements for residential landings and thresholds based on the 2016 california residential code.
Landing requirements for egress exterior doors.
The floor or landing shall be no more than 1 inch lower than the threshold of the doorway.
Where a stairway of two or fewer risers is located on the exterior side of a door other than the required exit.
This handout is intended to provide only general information.
Doors other than the required egress door shall be provided with landings or floors not more than 7 3 4 inches 196 mm below the top of the threshold.
There shall be a floor or landing at the top and bottom of each stairway.
D sliding door with swing out feature.